Guides & Insights·22 November 2026

Valve islands and control heads: automating process valves with Bürkert AirLINE

Valve islands vs control heads for process automation: how Bürkert AirLINE (8652, 8653, 8644, 8650), pilot valves (6519, 6524) and control heads (8681, 8691) fit together.

Territory Instruments

Marketing Team

Share
Valve islands and control heads: automating process valves with Bürkert AirLINE

Every pneumatic process valve needs a pilot valve to switch its air and, usually, feedback to confirm its position. You can do that centrally with a valve island in the control cabinet, or at the valve with a control head. The right architecture depends on valve count, distance, hygiene and hazardous-area requirements.

This guide explains both approaches using Bürkert's AirLINE valve islands, pilot valves and control heads, from the Type 8652 to the Type 8681.

Centralised: valve islands in the cabinet

A valve island groups many pilot valves on one manifold with a single fieldbus connection, and air lines run out to each valve. It is efficient when valves are clustered and the cabinet is close.

  • The Bürkert Type 8652 AirLINE is developed for process automation. Bürkert lists diagnostics on an LC display in clear text and symbols, safety-related shut-off of valves, PROFINET S2 system redundancy, check valves in the exhaust ducts against unplanned actuation, and Ex variants for ATEX/IECEx Zone 2 and Class I, II, III Div 2.
  • The Type 8644 AirLINE combines fieldbus modules, pilot valves and I/O on a standard rail, with direct connection to the WAGO I/O System 750.
  • For Zone 1/21, the Type 8650 AirLINE Ex uses intrinsically safe electronics and valves that can be replaced during operation, controlled via PROFINET IO or PROFIBUS DP with Siemens SIMATIC ET 200iSP I/O.

In the field: IP65/67 valve islands

When there is no cabinet near the valves, the Type 8653 AirLINE Field is an IP65/67 valve island designed for installation in the field, with CANopen, IO-Link or büS interfaces and the same diagnostics and pneumatic safety functions.

Decentralised: control heads on each valve

A control head sits on top of the valve actuator and integrates the pilot valves, position sensing and communication. Air tubing to the valve disappears, and wiring is one bus cable.

  • The Bürkert Type 8691 is designed for ELEMENT Type 21xx valves, with a contact-free inductive position sensor and teach function, a colour status display, integrated pilot air ducts with spring chamber aeration, and AS-Interface, IO-Link or büS. ATEX II cat. 3G/D and IECEx variants are available.
  • The Type 8681 is optimised for hygienic process valves and adapts to standard butterfly, ball, single-seat and double-seat valves, with three switching points, a coloured status LED and a magnetically encoded manual override that works with the housing closed.
Valve island (8652 / 8644) Field valve island (8653) Control head (8681 / 8691)
Location Control cabinet Field, IP65/67 On each valve
Air tubing to valves One line per valve Short lines from the field island None; pilot air integrated
Position feedback Separate sensors or wiring Separate sensors Integrated, teach function
Best fit Many valves near a cabinet Valve clusters without a cabinet Hygienic plants, spread-out valves

Single pilot valves for actuators

Not every valve justifies an island or a control head. For individual quarter-turn actuators and process valves, the Type 6519 pilot valve offers 3/2, 5/2 or 5/3-way functions with G 1/4, 1/4 NPT or NAMUR flange connections and Ex variants; Bürkert states that certain monostable functions can reach SIL 2 depending on the safety architecture. The compact Type 6524 uses a flipper pilot for high pressures with low power and is suited to valve island use.

Selection checklist

  1. Count the valves and map how far they are from the cabinet.
  2. Many valves near a cabinet: a valve island such as the 8652 or 8644.
  3. Clusters in the field: the 8653 AirLINE Field.
  4. Hygienic or spread-out valves: control heads, the 8681 for hygienic valves or the 8691 for ELEMENT valves.
  5. Hazardous areas: check Zone 2 variants of the 8652 or the 8650 for Zone 1/21, and Ex pilot valves such as the 6519.

Territory Instruments can quote Bürkert AirLINE islands, pilot valves and control heads configured for your fieldbus and valve list.

Frequently asked questions

What is the difference between a valve island and a control head?

A valve island groups many pilot valves on one manifold, usually in a cabinet, with air lines out to each valve. A control head mounts on an individual process valve and integrates its pilot valves, position feedback and communication.

Which Bürkert valve island can be mounted in the field?

The Type 8653 AirLINE Field is designed for field installation with IP65/67 protection.

Is there a Bürkert valve island for Zone 1?

Yes. The Type 8650 AirLINE Ex is designed for potentially explosive atmospheres in Zones 1/21 with intrinsically safe electronics and valves.

Which control head suits hygienic butterfly and double-seat valves?

The Bürkert Type 8681 is optimised for hygienic process valves and adapts to standard butterfly, ball, single-seat and double-seat valves.

Territory Instruments

Marketing Team

Share

Related articles

Choosing a gas analyser: laser CRDS vs process mass spectrometry vs calorimeters and dew point
Guides & Insights23 November 2026

Choosing a gas analyser: laser CRDS vs process mass spectrometry vs calorimeters and dew point

Laser CRDS, quadrupole mass spectrometry or a calorimeter and dew point transmitter? How Tiger Optics, Extrel and COSA Xentaur analysers from Process Insights compare for trace impurities, multi-component process gas and fuel gas quality.

Territory Instruments·Marketing Team

Online water quality monitoring: TOC, COD, BOD and toxicity with LAR analysers
Guides & Insights23 November 2026

Online water quality monitoring: TOC, COD, BOD and toxicity with LAR analysers

TOC, COD, BOD or toxicity? What each water quality parameter tells you and how the LAR QuickTOCultra, QuickCODultra, QuickCODlab, BioMonitor and NitriTox analysers from Process Insights measure them in wastewater and process water.

Territory Instruments·Marketing Team

Ball vs butterfly vs segment valves: choosing Valmet Neles rotary valves
Guides & Insights23 November 2026

Ball vs butterfly vs segment valves: choosing Valmet Neles rotary valves

Ball, butterfly or segment valve? How Valmet Neles D-Series, Series X, BW, Neldisc L6 and R-Series segment valves compare for isolation, control and slurry duty.

Territory Instruments·Marketing Team

Discussed products & recommended categories

Bürkert Type 8652 AirLINE Valve Island

Bürkert Type 8652 AirLINE Valve Island

Bürkert Type 8653 AirLINE Field Valve Island

Bürkert Type 8653 AirLINE Field Valve Island

Bürkert Type 8644 AirLINE Electropneumatic Automation System

Bürkert Type 8644 AirLINE Electropneumatic Automation System

Bürkert Type 8650 AirLINE Ex Automation System for Hazardous Areas

Bürkert Type 8650 AirLINE Ex Automation System for Hazardous Areas

Bürkert Type 6519 Pilot Solenoid Valve 3/2, 5/2, 5/3-Way (NAMUR)

Bürkert Type 6519 Pilot Solenoid Valve 3/2, 5/2, 5/3-Way (NAMUR)